Applications
- Abdominal
- Small parts and superficial
- Pediatric
- Musculoskeletal
- Obstetrical
- Gynecological and fertility
- Prostate
- Vascular
- – Cerebrovascular
- – Peripheral vascular
- – Intraoperative vascular
- Transcranial Doppler
- Cardiac
- – Adult
- – Pediatric
- – Transesophageal
- – Stress
Imaging Modes
- 2D
- Color Doppler
- Color Power Angio® Imaging (CPA)
- Directional Color Power Angio Imaging
- M-mode
- Pulsed wave Doppler
- Color M-mode
- Continuous wave Doppler
- 3D (part of OB/Gyn application package)
- Dual mode
- Duplex for simultaneous 2D and Doppler
- Triplex mode for simultaneous 2D, Doppler and color/CPA
- Fusion Signal Processing
- Tissue Harmonic Imaging (THI)
- Intelligent Doppler
- Panoramic Imaging (HD system only)
- MicrofineTM Focusing (HD system only)
- 103 cm
- 40.5 in
Physical Dimensions
- Depth: 103 cm/40.5 in; Width: 54.6 cm/21.5 in; Ground clearance: 11.4 cm/4.5 in; Height (adjustable): 129.5–147.5 cm/51–58 in; Control panel height (adjustable): 84.6-99.7 cm/33-39.3 in; Wheel base: 53.3 cm wide by 53.3 cm deep/21 in x 21 in; Wheels: 12.7 cm/5 in diameter, 9.5 cm/3.8 in wide; Weight: 100 kg/220 lbs including display (no peripherals)
- Imaging Modes continued
- Pulse Inversion Harmonic Imaging (HD system only)
- Adaptive Doppler (HD system only)
- Adaptive Color Doppler (HD system only)
- Tissue Doppler Imaging (HD system only)
Monitor
- 256 x 202.5 mm/15 inch
- Raises, lowers and rotates with control panel
- Swivels +/- 120 degrees
- Tilts +15/- 10 degrees
- VGA (800 x 600 @ 75 Hz) non-interlaced RGB
- Resolution: 800 pixels per line
- 0.28 mm dot pitch
- Brightness, contrast and color temperature controls
Gray Shades
Control Panel and User Interface
- Control panel can be raised, lowered and rotated more than 300 degrees
- Easy-to-use control panel with primary controls readily accessible and logically grouped
- Alphanumeric keyboard: QWERTY keyboard with globalization key for conversion to local language (English, French, German, Italian and Spanish)
- Trackball with Select and Enter keys for easy navigation on the system
- Integrated stereo speakers
- Imaging mode keys: 2D, Color Power Angio, M-mode, Color Doppler, Continuous Wave Doppler (CW), Pulsed Wave Doppler (PW)
- 2D image controls: Depth, Dual Left, Dual Right, Freeze, THI, Zoom, Focus
- Image enhancement controls: Dynamic Range, Focus, Gain, Persistence, Post-processing Map, Smooth
- Patient specific optimization keys: Fusion, Probe (transducer select), THI
- Quantitative controls: Measure, Menu, Delete, Trackball
- Doppler/Color controls: Angle/Steer, Spectral, Scale, Baseline, Gain, Power, Volume, Plex
- Image acquisition keys: Review, Report, VCR, Acquire and three user-defined record keys supporting external print/video options
- Annotation controls: Label, Menu, Delete, Arrow, Bodymarker
- Secondary control group: Six soft keys whose functions change dynamically based on the currently-active mode, preset, or system function
- Function keys: Microphone, Patient, Preset, Setup
- Four option keys activated with additionally purchased features such as 3D, stress echo, panoramic and Tissue Doppler imaging
- Online Help key
- Lateral Gain Compensation (LGC) slide pot controls
- Time Gain Compensation (TGC) slide pot controls
Acquisition Frame Rate
- Greater than 90 frames/second (dependent on transducer, field of view, depth and angle)
- Standard Imaging Features – available on all EnVisor systems
- 256-channel broadband digital beamformer for accurate, high-resolution imaging that supports three Fusion (patient specific optimization) settings
- Tissue Harmonic Imaging — improves grayscale image clarity by reducing clutter and sharpening tissue borders for improved image quality in difficult-to-image patients
- Triplex mode — displays tissue movement and blood flow in 2D, color/CPA and PW Doppler simultaneously
- Trapezoidal Linear Array — expands field of view up to 15 degrees on each side (available with vascular and general imaging application packages)
- Color compare — simultaneously displays real-time Color Power Angio, Color Doppler and grayscale images side by side
- 3D surface rendering (available with OB/Gyn application package)
- Automatic color invert — automatically inverts color maps to maintain selected color-coding when the linear steering angle passes through vertical
- Automatic Doppler trace — traces frozen spectral display to calculate and display user-selected measurements in most presets
- Body markers — displays body-part icons appropriate for the active preset and indicates the relative position of the transducer
- Full-screen M-mode and Doppler — improves diagnoses by enabling easier, more accurate caliper placement
- Intelligent Doppler Imaging— automatically maintains optimal angle-to-flow to assist in delivering accurate and consistent Doppler velocity measurements (available with vascular and general imaging application packages on linear transducers only)
- Multiple focal zones — brings tiny structures and fine textures into sharp focus
- Quick text — allows easy annotation at any time during an exam
- Label — places, moves, erases, modifies or appends predefined text labels, typed text or arrows
- Online help
Analysis and Review Features
- Comprehensive measurements, calculations and application-specific reports with embedded images, including expanded cardiac, vascular and OB/Gyn capabilities for thorough exam documentation
- Extensive image management capability —including thumbnail image review, to view and edit images, Cineloops and reports
- CD recordable single session for archiving images
- Study manager allows user to digitally acquire, review and edit complete patient studies
- Floppy disk drive (3.5") — enables system configuration backup and retrieval, including user-defined presets and trending data for OB exams
- Ability to export AVI and BMP images to 3.5" floppy disk, CD or magneto-optical disk (MOD) for viewing on a PC
- Loop edit controls
- Ability to archive studies (images only) to MOD (with DICOM media option)
Cineloop Review
- Acquisition, storage in memory, and display in real-time and duplex modes of up to 300 frames (or 30 seconds) of 2D and color images for retrospective review and image selection
- Single frames of Doppler data and M-mode images can be archived to print or electronic media
- Trackball control of frame-by-frame image selection
- Variable playback speed
- Trim capability
- Functions in 2D and Tissue Harmonic Imaging, M-mode, PW Doppler, CW Doppler, Color Doppler, Color Power Angio imaging and Tissue Doppler imaging
Cart Features
- Back deck shelf to support peripherals
- Standard CD recordable and 3.5" floppy drives (3.5" MOD drive available with DICOM Media option)
- System can be configured with up to four (4) transducer connectors
- Features four full-swivel wheels, for maximum maneuverability; two-wheel swivel lock and brake
- Performance Features – available on EnVisor HD systems
- All of the Standard Imaging Features, plus:
- 512-channel broadband digital beamformer with five Fusion (patient specific optimization) settings for added diagnostic power
- Parallel processing in 2D and color modes for faster frame rates
- Adaptive Color for automatic optimization of color or Color Power Angio frequencies, ensuring excellent sensitivity and color penetration
- Pulse Inversion Harmonic Imaging setting achieves broader bandwidths in harmonic modes for further gains in axial resolution and overall clarity
- Microfine focusing — up to eight focal zones on selected transducers
- Panoramic imaging for extended field of view
- Adaptive Doppler boosts weak signals to improve spectrum visibility and enhances pulsed-wave audio signals for precise flow assessment
- Performance Features continued
- Tissue Doppler Imaging (TDI) on sector transducers uses color to display direction and timing of myocardial function
- Other Options
- External video/print option: 60 Hz NTSC/50 Hz PAL
- Stress Echo package with foot switch
- Image recorders (VCR, B/W thermal printer, color printer)
- Foot switch — includes two user definable record funtions
- Biopsy kits available for the following transducers:
- – c3540
- – L1038
- – PA 4-2
- – CA 5-2
- – E6509
- – L7535
- – L5035
- DICOM
- – DICOM Media includes 3.5" MOD drive for image storage and integrated on-board image extended memory
- – DICOM Basic includes DICOM print and storage modalities with extended on-board image memory
- Additional (fourth) transducer connector
- Miscellaneous System Data
Localization Options
- Software: English, French, German, Italian and Spanish
- Training and user documentation: English, French, German, Italian, Spanish, Japanese, simplified Chinese, Polish, Portuguese and Russian
- Online help: English, French, German, Italian, Spanish, Portuguese, Russian and Polish
Power Requirements
- Power: 1150VA
- Frequency: 47 to 63 Hz
- Voltage: 90V to 240V AC
Power Cords
- Available for electrical standards worldwide
Electrical Safety Standards
- CSA C22.2 No. 601.1
- IEC 60601-1
- UL-2601
- EN60601-1
Environmental
- Temperature
- – System: 0-40 degrees C at 20-80 percent relative humidity
- – VCR and printers: 0-40 degrees C at 80 percent relative humidity (non-condensing)
- Heat Dissipation — <4000 BTUs/hour (fully loaded)
Input/Output Ports
- Five available ports:
- – Standard USB interface for support of qualified plain paper printers
- – Composite video: output to external monitor, VCR or printer (only available with external video option)
- – External print trigger (only available with external video option)
- – LAN connector — used with DICOM Basic
- – Foot switch port (optional) — for connecting the optional foot switch
Peripherals
- Panasonic MD835P Super-VHS video cassette recorder
- – Resolution: >400 lines
- – Video format: NTSC or PAL
- – Model number: 77616A (NTSC); 77626A (PAL)
- – Media part number: 77612-91920
- – Dimensions (h/w/d): 13.2 x 27 x 39.4 cm; (5.2 x 10.5 x 15.4 in)
- – Weight: 7.5 kg (16.5 lbs)
- B/W Thermal Printer
- – Sony UP D895MD digital black and white printer (USB input)
- Color Printer
- – UPD21-MD Sony digital color printer (USB input)
- System supports a range of plain paper printers
- Transducers
Transducer selection
- Electronic switching of up to four transducers
- System supports up to 13 transducers to meet a wide range of clinical needs
- Transducers
PA 4-2 Broadband Sector
- – 2-4 MHz extended operating frequency range
- – Provides high-resolution images for abdominal, cardiac and OB/Gyn applications
- – Supports 2D, color, PW / CW Doppler, Tissue Harmonic Imaging and Color Power Angio Imaging
s4 Broadband Sector
- – Supported on EnVisor HD system only
- – 2-4 MHz extended operating frequency range
- – Provides high-resolution images for abdominal, cardiac and OB/Gyn applications
- – Supports 2D, color, PW/ CW Doppler, Tissue Harmonic Imaging and Color Power Angio Imaging
s8 Broadband Sector
- – 3-8 MHz extended operating frequency range
- – High-resolution images for pediatric and OB/Gyn applications
- – Supports 2D, color, PW / CW Doppler and Color Power Angio Imaging
s12 Broadband Sector
- – 5-12 MHz extended operating frequency range
- – Provides high-resolution images for pediatric echo and neonatal cephalic applications
- – Supports 2D, color, PW / CW Doppler and Color Power Angio Imaging
Omni II Broadband Sector Multiplane TEE
- – 4.6-6 MHz extended operating frequency range
- – Transesophageal imaging
- – Supports 2D, color, PW / CW Doppler and Color Power Angio Imaging
CA 5-2 Broadband Curved
- – 2-5 MHz extended operating frequency range
- – Provides high-resolution images for abdominal and OB/Gyn applications
- – Supports 2D, color, PW Doppler, Tissue Harmonic Imaging and Color Power Angio Imaging
c3540 Broadband Curved
- – Supported on EnVisor HD system only
- – 2-5 MHz extended operating frequency range
- – Provides high-resolution images for abdominal and OB/Gyn applications
- – Supports 2D, color, PW Doppler, Tissue Harmonic Imaging and Color Power Angio Imaging
E6509 Broadband Curved
- – 5-7.5 MHz extended operating frequency range
- – Provides high-resolution endocavity imaging for OB/Gyn and prostate applications
- – Supports 2D, color, PW Doppler, Tissue Harmonic Imaging and Color Power Angio Imaging
L1038 Broadband Linear
- – 5-12 MHz extended operating frequency range
- – 10 degrees of trapezoidal imaging
- – Provides high-resolution images for superficial applications
- – Supports 2D, color, PW Doppler and Color Power Angio Imaging
L5035 Broadband Linear
- – 3.5-5.6 MHz extended operating frequency range
- – 15 degrees of trapezoidal imaging
- – Provides high-resolution images for vascular applications
- – Supports 2D, color, PW Doppler and Color Power Angio Imaging
L7535 Broadband Linear
- – 4.5-7.5 MHz extended operating frequency range
- – 15 degrees of trapezoidal imaging
- – Provides high-resolution images for superficial imaging applications
- – Supports 2D, color, PW Doppler and Color Power Angio Imaging
15-6L Broadband Compact Linear
- – 6-15 MHz extended operating frequency range
- – 8 degrees of trapezoidal imaging
- – Provides high-resolution images for intraoperative vascular applications
- – Supports 2D, color, PW Doppler and Color Power Angio Imaging
D1914 Cardiac Non-imaging
- – 1.9 MHz imaging
- – Non-imaging CW Doppler probe for cardiac applications