24/7 Nationwide Service
15-30 Minute Response Time
Try It Now
Contact Us Contact Us
877-891-0084 877-891-0084
Ultrasound Repair
  • Home
  • About
    • Leadership Team
  • Repairs
    • Ultrasound Repair
    • Transducer Repair
    • Probe Evaluation
    • Ultrasound Service Contracts
  • Sales
    • Financing Program
    • C-arm Solutions
    • New Ultrasound Systems
    • Refurbished Ultrasound Systems
    • Portable Ultrasound Systems
    • Alpinion E-Cube
  • News
  • Contact

  • SONODEPOT
  • PHILIPS HD 11 XE

PHILIPS HD 11 XE

PHILIPS HD 11 XE

System Specifications

  • Applications
  • Abdominal
  • Small parts and superficial
  • Pediatric
  • Musculoskeletal
  • Obstetrical
  • Gynecological and fertility
  • Prostate
  • Vascular
  • – Cerebrovascular
  • – Peripheral vascular
  • – Intraoperative vascular
  • Transcranial Doppler
  • Cardiac
  • – Adult
  • – Pediatric
  • – Transesophageal
  • – Stress
  • Contrast imaging
  • ICE Imaging (Intracardiac Echocardiography)

Imaging Modes

  • 2D grayscale imaging with advanced Fusion frequency
  • compounding technology
  • Tissue Harmonic Imaging with Pulse Inversion technology
  • SonoCT beam-steered real-time compound imaging
  • Harmonic SonoCT imaging
  • XRES adaptive image processing technology
  • iSCAN intelligent scanning for one-button TGC, gain and
  • compression map optimization
  • Simultaneous 2D and M-mode
  • Color M-mode
  • Anatomical M-mode
  • – Trace can be generated or modified post-Freeze, from 2D image data in Quick Review buffer
  • Adaptive Color Doppler for automatic selection of optimal color frequency
  • Color Tissue Doppler Imaging
  • Pulsed wave Tissue Doppler Imaging
  • Color Power Angio Imaging (CPA) and directional CPA
  • Intelligent Doppler for maintaining specified scanning angles during flow adjustments
  • Adaptive Doppler for boosting weak signals and reducing noise
  • Duplex 2D/PW Doppler
  • High-PRF pulsed wave (PW) Doppler
  • Color compare
  • – Real-time color/2D images
  • Triplex 2D, CPA, PW Doppler
    • Dual imaging with:
    • – Independent cineloop buffers
    • – Mixed mode display with one image live while other is frozen, for example 2D/2D, 2D/color, color/color, color/CPA
    • High Definition zoom (write zoom)
    • Reconstructed zoom with pan (read zoom)
    • Panoramic imaging
    • Trapezoidal imaging
    • Freehand 3D and MPR imaging
    • Automated 3D and real-time 4D imaging with harmonics and color modes
    • Automated 3D fetal echo STIC (Spatio-Temporal Image
    • Correlation)
    • Chroma imaging in 2D, 3D, 4D, MPR, panoramic, M-mode, Doppler modes and CW/PW
    • Contrast imaging
    • Gray Shades
    • 256 (8 bits) in 2D, M-mode and Doppler spectral analysis
    • Acquisition Frame Rate
    • 2D frame rate acquisition greater than 785 frames per second (dependent on transducer, field of view, depth and angle)
    • Color frame rate acquisition greater than 320 Hz (dependent on transducer, field of view, depth and angle)
    • The automated volume transducers are lightweight and small with an ergonomic design for improved user comfort during exams. The C6-3 smaller curved array transducer improves intercostal access. The new BP10-5ec transducer supports biplane prostate imaging

 

Transducer Selection

  • Electronic switching of transducers using up to five
  • connector ports
  • Dedicated (Pedoff) CW and PW Doppler connector
  • User customizable imaging presets for each transducer
  • Multiple user-selectable transmit focal zones; up to eight focal zones on selected transducers
  • Continuous dynamic receive focusing on all transducers
  • S4-2 Broadband Sector Array
  • Steerable CW Doppler, PW Doppler, High-PRF Doppler, color Doppler, Color Power Angio, Tissue Doppler Imaging,

XRES and harmonic imaging

  • Adult cardiac, deep abdominal, obstetrical and gynecological applications
  • Supports reusable plastic bracket with disposable biopsy guides
  • Transcranial Doppler S3-1 Broadband Sector Array
  • Steerable CW Doppler, PW Doppler, High-PRF Doppler, color Doppler, Color Power Angio, Tissue Doppler Imaging, freehand 3D, XRES and harmonic imaging
  • Field of view: 90 degrees
  • Contrast imaging
  • General abdominal and adult cardiology applications;

 

S8-3 Broadband Sector Array

  • Field of view: 90 degrees
  • Steerable PW Doppler, CW Doppler, High-PRF Doppler, color Doppler, Color Power Angio, Tissue Doppler Imaging, freehand 3D and XRES imaging
  • Adult and pediatric cardiology applications; fetal echo

System Specifications

  • S12-4 Broadband Sector Array
  • Field of view: 90 degrees
  • Steerable PW Doppler, CW Doppler, High-PRF Doppler, color Doppler, Color Power Angio, XRES and Tissue Doppler Imaging
  • Pediatric cardiology applications S7-2omni Broadband Sector Array
  • 180 degrees electronic rotation, field of view: 90 degrees
  • Steerable PW Doppler, CW Doppler, High-PRF Doppler, color
  • Doppler, Color Power Angio, Tissue Doppler Imaging, XRES and
  • harmonic imaging
  • Adult transesophageal applications OmniPlane Adapter
  • Enables system to support use of TEE OmniPlane III transducer (Model #21378A) S7-3t Broadband Sector Array
  • 180 degrees mechanical rotation, field of view: 90 degrees
  • Steerable PW Doppler, CW Doppler, High-PRF Doppler, color Doppler, Color Power Angio, Tissue Doppler Imaging, XRES and harmonic imaging
  • Pediatric and small adult transesophageal applications
  • C5-2 Broadband Curved Array
  • Steerable pulsed Doppler, color Doppler, Color Power Angio, SonoCT, harmonic, Panoramic and XRES imaging
  • Field of view: 75 degrees
  • Contrast imaging
  • General purpose abdominal, obstetrical and gynecological applications
  • Supports reusable plastic bracket with disposable biopsy guide (14–25 gauge) C6-3 Broadband Curved Array
  • Steerable pulsed Doppler, color Doppler, Color Power Angio, SonoCT, harmonic, Panoramic and XRES imaging
  • Field of view: 72 degrees
  • Contrast imaging
  • General purpose abdominal, obstetrical and gynecological applications
  • Supports reusable, multi-angle, plastic bracket with disposable biopsy guide (14–25 gauge) C8-5 Broadband Curved Array
  • Field of view: 90 degrees
  • Steerable pulsed Doppler, color Doppler, Color Power Angio, harmonic, freehand 3D, Panoramic and XRES imaging
  • Neonatal, cephalic imaging and pediatric abdominal
  • Supports reusable plastic bracket with disposable biopsy guide (14–25 gauge)
  • Biopsy kit available C9-4 Broadband Curved Array
  • Field of view: 64 degrees
  • Steerable pulsed Doppler, color Doppler, Color Power Angio, freehand 3D, Panoramic, SonoCT and XRES imaging
  • General purpose small adult and pediatric abdominal, obstetrical and gynecological applications
  • Supports reusable plastic bracket with disposable biopsy guide (dual angle) (14–25 gauge) BP10-5ec Broadband Biplane Curved Array
  • Biplane intersecting sagittal and transverse sectors, 8 mm radii
  • of curvature, fields of view: 126 degrees
  • Steerable pulsed Doppler, color Doppler, Color Power Angio, harmonic, freehand 3D, Panoramic, SonoCT and XRES imaging
  • Endorectal and endovaginal applications for urology
  • Supports disposable transrectal biopsy guide (16–18 gauge)
  • C9-5ec Broadband Curved Array
  • End-fire sector, 8 mm radius of curvature, field of view:
  • 150 degrees
  • Steerable pulsed Doppler, color Doppler, Color Power Angio, Freehand 3D, Panoramic, SonoCT and XRES imaging
  • Endocavitary applications including endovaginal and endorectal
  • Supports reusable plastic bracket with disposable biopsy guide
  • (16–22 gauge) C8-4v Broadband Curved Array
  • End-fire sector, 11 mm radius of curvature, field of view:
  • 135 degrees
  • Steerable pulsed Doppler, color Doppler, Color Power Angio,
  • Panoramic, SonoCT and XRES imaging
  • Endovaginal applications
  • Supports reusable stainless steel biopsy guide (15–22 gauge) 
  • 3D9-3v Broadband Curved Array
  • Field of view: 130 degrees
  • Supports high resolution 2D imaging
  • Supports high resolution, quantitative, single sweep 3D
  • volume acquisition
  • Supports 4D imaging
  • Steerable pulsed Doppler, color Doppler, Color Power Angio,
  • SonoCT, XRES, Panoramic and harmonic imaging
  • Endovaginal applications
  • Supports disposable biopsy guide (16–22 gauge)
  • V6-2 Broadband Curved Array
  • Supports high resolution 2D imaging
  • Supports high resolution, quantitative, single sweep 3D
  • volume acquisition
  • Supports 4D imaging up to 30 volumes per second
  • Supports 3D Fetal Echo STIC imaging
  • Supports 3D Color Doppler
  • Field of view: 70 degrees
  • Steerable pulsed Doppler, High-PRF Doppler, color Doppler,
  • Color Power Angio, Freehand 3D, Panoramic, SonoCT, XRES,
  • and harmonic imaging
  • General purpose abdominal, obstetrical and gynecological
  • applications
  • Supports reusable plastic bracket with disposable biopsy guide
  • (dual angle) (14–23 gauge)
  • V8-4 Broadband Curved Array
  • Supports high resolution 2D imaging
  • Supports high resolution, quantitative, single sweep 3D
  • volume acquisition
  • Supports 4D imaging up to 30 volumes per second
  • Supports 3D Fetal Echo STIC imaging
  • Supports 3D Color Doppler
  • Field of view: 85 degrees
  • Steerable pulsed Doppler, High-PRF Doppler, color Doppler,
  • Color Power Angio, SonoCT, XRES, Panoramic and
  • harmonic imaging
  • General purpose small adult and pediatric abdominal, obstetrical
  • and gynecological applications
  • Supports reusable plastic bracket with disposable biopsy guide
  • (dual angle) (14–23 gauge)
  • L9-3 Broadband Linear Array
  • Fine pitch, 160 element, high-resolution linear array
  • Harmonics capable
  • 15 degrees of trapezoid imaging
  • 38 mm effective aperture length
  • Steerable pulsed Doppler, color Doppler, Color Power Angio,
  • SonoCT, XRES, Panoramic and harmonic imaging
  • General imaging, vascular and superficial imaging applications
  • Supports reusable plastic bracket with disposable biopsy guide
  • (dual angle) (14–25 gauge)
  • L8-4 Broadband Linear Array
  • Fine pitch, 160 element, high-resolution linear array
  • 15 degrees of trapezoid imaging
  • 38 mm effective aperture length
  • Steerable pulsed Doppler, color Doppler, Color Power Angio,
  • SonoCT, XRES, Panoramic and harmonic imaging
  • General imaging, vascular and superficial imaging applications
  • Supports reusable plastic bracket with disposable biopsy guide
  • (dual angle) (14–25 gauge)
  • L12-3 Broadband Linear Array
  • 10 degrees of trapezoidal imaging
  • 35 mm effective aperture length
  • Steerable pulsed Doppler, color Doppler, Color Power Angio,
  • SonoCT, XRES, Panoramic and harmonic imaging
  • High resolution superficial applications including small parts,
  • breast, superficial vascular and musculoskeletal imaging
  • Supports reusable stainless steel biopsy guide
  • L12-5 50 mm Broadband Linear Array
  • Fine pitch, 256 element, high-resolution linear array
  • 50 mm effective aperture length
  • 10 degrees of trapezoidal imaging
  • Steerable pulsed Doppler, color Doppler, Color Power Angio,
  • Panoramic, SonoCT and XRES imaging
  • High resolution superficial applications including small parts,
  • breast, vascular and musculoskeletal imaging
  • Supports reusable plastic bracket with disposable biopsy guide
  • (up to 14 gauge)
  • L15-7io Broadband Compact Linear Array
  • 23 mm effective aperture length
  • 8 degrees of trapezoidal imaging
  • Steerable pulsed Doppler, color Doppler, Color Power Angio,
  • Panoramic and XRES imaging
  • High resolution intraoperative vascular applications
  • D2cwc (Continuous Wave and Pulsed Wave) Transducer
  • Dedicated 2 MHz continuous wave Doppler
  • Adult cardiology applications
  • D5cwc (Continuous Wave) Transducer
  • Dedicated 5 MHz continuous wave Doppler
  • Deep venous and arterial applications
  • D2tcd (Pulsed Wave) Transducer
  • Transcranial Doppler applications
  • Peripheral vascular applications

Advanced Imaging Controls

  • 2D Grayscale Imaging
  • Frame rate selection
  • 8-level digital reconstructed zoom with pan capability
  • High Definition (HD) zoom concentrates all image processing
  • power into a user-defined area of interest; possible to combine
  • HD Zoom with Pan Zoom
  • Image orientation marker
  • Cineloop image review
  • Persistence, adjustable in real time and cineloop review
  • Selectable 2D compression settings
  • Sector size and steering control for sector and curved array
  • image formats
  • Dual imaging with independent cineloop buffers
  • Selectable line density
  • Up to eight transmit focal zones plus separation control
  • Chroma imaging with multiple color maps
  • 256 (8 bits) discrete gray levels
  • 2D acquisition frame rates up to 785 frames per second
  • (dependent on probe, field of view, depth and angle)
  • 9,216 digitally processed channels
  • Fusion Signal Processing
  • Multi-channel frequency compounding for improved tissue
  • contrast resolution and textural perception

System Specifications

  • Up to five settings for patient-specific adjustments in 2D mode
  • One button to emphasize between resolution, texture
  • or penetration
  • iSCAN Intelligent Optimization
  • One-touch image optimization
  • – In 2D mode, one button automatic adjustment of:
  • - TGC and Receiver Gain to achieve optimal uniformity and
  • brightness of tissues
  • - Compression curve based on the range of detectable
  • tissue signals
  • – In Doppler mode, one button automatic adjustment of:
  • - Doppler scale based on detected velocity
  • - Doppler baseline based on detected flow direction
  • Available on all curved, linear and phased (non cardiac presets)
  • array transducers
  • Operates in conjunction with SonoCT and XRES imaging
  • SonoCT Real-time Compound Imaging
  • High precision beam-steered image compounding for acquisition
  • of more tissue image information and reduction of angle
  • generated artifacts
  • Up to nine beam-steered lines of sight
  • Available on C5-2, C6-3, C9-4, BP10-5ec, C9-5ec, C8-4v, L8-4, L9-
  • 3, L12-3 and L12-5 50 mm transducers
  • 3D9-3v, V6-2 and V8-4 transducers in 2D modes only
  • Two modes of operation: Survey and Target
  • Operates in conjunction with Tissue Harmonic Imaging and
  • duplex Doppler
  • Operates in conjunction with XRES imaging
  • Available in contrast modes
  • XRES Adaptive Image Processing
  • Philips proprietary real-time processing technology that analyzes
  • image content down to pixel level
  • Applies adaptive enhancement to virtually eliminate noise and
  • sharpen margins/borders to improve conspicuity of tissue patterns
  • Processing available in live or frozen 2D image, as well as 3D/4D
  • MPRs and volume views
  • Available on all imaging transducers
  • Available in all imaging modes including color flow and Doppler
  • Operates in conjunction with SonoCT real-time compound imaging
  • on C5-2, C6-3, C9-4, C9-5ec, L8-4, L9-3, L12-3
  • and L12-5 50 mm transducers
  • Available on 3D9-3v, V6-2 and V8-4 transducers in 2D mode only

Imaging Modes

  • M-mode
  • • Available with all imaging transducers
  • • Selectable sweeping rates
  • • Time markers: 0.1 and 0.2 seconds
  • • Acquisition zoom capability
  • • Chroma colorization with multiple color maps
  • • Cineloop review for retrospective analysis of M-mode data
  • • Full-screen M-mode display facilitates diagnoses by enabling
  • easier, more accurate caliper placement
  • • Color M-mode on all sector transducers and C5-2, C8-4v
  • and C9-4 transducers
  • Anatomical M-mode
  • • Uses 2D image as a basis for M-mode analysis at a defined line,
  • independent of transducer orientation
  • • Makes it easier to keep the M-mode line perpendicular to the
  • anatomy, even in abnormally shaped or positioned hearts
  • • Provides data on direction, position and timing of any single echo
  • received from any point of the tissue for M-mode analysis in any
  • direction, for examining cardiac chamber diameters, LV regional
  • wall motion and location of accessory pathways
  • • Anatomical M-mode trace can be generated or modified
  • post Freeze
  • • Anatomical M-mode on all sector transducers, including S3-1,
  • S4-2, S7-2, S7-3t, S8-3, and S12-4
  • Spectral Doppler
  • • Display annotation including Doppler mode, scale (cm/sec or kHz),
  • Nyquist limit, pulse repetition frequency, wall filter setting, gain,
  • acoustic output status, sample volume size, normal/inverted, angle
  • correction and grayscale curve
  • • Adaptive Doppler boosts weak signals to improve spectrum
  • visibility and enhances pulsed-wave audio signals for precise
  • flow assessment
  • • Intelligent Doppler Imaging—automatically maintains optimal
  • angle-to-flow to assist in delivering accurate and consistent
  • Doppler velocity measurements (available with vascular and
  • general imaging application packages on linear transducers)
  • • Adjustable frequency/velocity display ranges
  • • 8-position zero baseline shift
  • • Normal/invert display around horizontal zero line
  • • Selectable sweep speeds
  • • Selectable grayscale curve for optimal display
  • • Selectable display format (1/3–2/3, 1/2–1/2, 2/3–1/3)
  • • Full-screen Doppler display improves diagnoses by enabling
  • easier, more accurate caliper placement
  • • Doppler review for retrospective analysis of Doppler data
  • Pulsed Wave (PW) Doppler
  • • Available on all imaging transducers
  • • Adjustable sample volume size: 0.05–2.63 cm
  • • Duplex mode—displays tissue movement and blood flow in 2D
  • and PW Doppler simultaneously
  • • Triplex mode—displays tissue movement and blood flow in 2D,
  • color/CPA and PW Doppler simultaneously
  • • High-PRF capability in all modes including Duplex and Triplex
  • • iSCAN optimization automatically adjusts scale and baseline
  • Steerable Continuous Wave (CW) Doppler
  • • Cardiac sector array transducers only
  • • Steerable through 90 degree sector
  • • Maximum velocity range: 19 meters per second
  • (transducer dependent)
  • Color Doppler
  • • Adaptive Color automatically optimizes color or Color
  • Power Angio frequencies, ensuring excellent sensitivity and
  • color penetration
  • • Color Compare simultaneously displays real-time Color Power
  • Angio, color Doppler, grayscale and TDI images side-by-side
  • • Automatic Color Invert automatically inverts color maps to
  • maintain selected color coding when the linear steering angle
  • passes through vertical
  • • Available on all imaging transducers
  • • Cineloop review
  • • Chroma 2D colorization with multiple color maps
  • • 256 color bins
  • • Continuously variable color steering
  • • Trackball-controlled color region of interest: size and position
  • • Maps, filters, color sensitivity, line density, smoothing, echo
  • write priority, color persistence, gain and baseline optimized
  • automatically by preset or is user selectable
  •  
  • • Velocity and variance displays
  • • Color/2D line density control
  • • Selection of color bar display units
  • • Color acquisition frame rates up to 320 frames per second
  • (dependent on probe, field of view, depth and angle)
  • Contrast Imaging
  • • System optimized for detecting harmonic agent signatures
  • • Variable low Mechanical Index (MI) and flash modes
  • • Pulse Inversion Harmonic imaging on the S3-1 transducer for
  • cardiac and abdominal applications and the C5-2 transducer
  • for general abdominal applications
  • • Start/Stop timer
  • • On-screen indicators are activated when contrast is selected
  • Tissue Harmonic Imaging (THI)
  • • Second harmonic processing reduces artifacts and improves
  • image clarity
  • • Incorporates patented pulse inversion phase cancellation
  • technology for maximum detail resolution during harmonic imaging
  • • Extends high performance imaging capabilities to all patient
  • body types
  • • Supports SonoCT and XRES modes
  • • Available on the S7-2omni, S7-3t, S4-2, S3-1, C5-2, BP10-5ec,
  • L12-3, L8-4, 3D9-3v, V6-2 and V8-4 transducers
  • Color Power Angio Imaging (CPA)
  • • Highly sensitive mode for small vessel visualization
  • • Available on all imaging transducers
  • • Fully user-configurable
  • • Cineloop review
  • • User-definable presets
  • • Multiple maps including directional CPA
  • • Individual controls for gain, filters, sensitivity, echo write priority
  • and color invert
  • • Adjustable CPA region of interest: size and position
  • • User-selectable persistence
  • • TGC control
  • • Write priority
  • • Color compare
  • System Specifications
  • Tissue Doppler Imaging (TDI)
  • • Color TDI uses color to display direction and timing of
  • myocardial function
  • • Pulsed wave Tissue Doppler Imaging (TDI) for velocity mapping of
  • cardiac tissue and vessel wall motion
  • • Available on all sector transducers
  • • Simultaneous or duplex mode of operation in conjunction with 2D,
  • color Doppler and color TDI
  • • LGC and TGC controls
  • Freehand 3D and MPR Imaging
  • • Qualitative grayscale volume acquisition supported on all
  • imaging transducers
  • • Volume display with surface rendering (transparency, brightness
  • and lighting controls)
  • • Multiplanar view display
  • • Specialized algorithms and maps maximize three dimensional
  • display
  • • Trim tools on both volume and multiplanar reconstructed
  • (MPR) views
  • • Supported by XRES to reduce noise artifacts
  • • Color compare
  • Automated 3D, 4D and MPR Imaging
  • • Quantitative 3D volume acquisition supported on V8-4, V6-2
  • and 3D9-3v transducers
  • • Ability to acquire and display up to 30 volumes per second in 4D
  • • Color 3D imaging
  • • High resolution scan and review mode
  • • Multiple display formats including full screen, 2-up and 4-up for
  • rendered volume and multiplanar images include full screen, 4-up
  • and expanded dual
  • • Volume display with surface rendering (transparency, brightness
  • and lighting controls)
  • • Specialized algorithms and maps maximize three dimensional
  • display
  • • Individual controls for manipulating the on-screen 3D rendering
  • and display options
  • • Region of Interest (ROI) trim tools on both volume and
  • multiplanar reconstructed (MPR) views
  • • V8-4, V6-2 and 3D9-3v transducers support XRES and SonoCT to
  • reduce noise artifacts
  • • Able to perform distance, ellipse, trace and volume measurements
  • Fetal STIC (Spatio-Temporal Image Correlation) Imaging
  • • Presents the heart beating in a multiplanar display, preserving
  • spatial and temporal relationships
  • • Utilizes MPR views and cine capabilities for evaluating fetal
  • heart anatomy
  • • System supports capabilities to perform the spin technique to
  • assess pathology
  • • Fetal Echo STIC supports image capture in gray scale only or
  • combined with Color Doppler
  • • Useful for easy detection of fetal heart anomalies during routine
  • obstetrical exams
  • Expanded Field of View
  • • Panoramic Imaging
  • – Extended field of view composite imaging
  • – Full zoom, pan, cineloop review and image rotation capabilities
  • – Available on linear, curved and sector (non-cardiac presets)
  • array transducers
  • • Trapezoidal imaging
  • – Expands field of view on linear array transducers up to 15
  • degrees on each side in vascular and general imaging applications
  • Stress Echo
  • • Fully integrated stress echo module
  • • 3 fixed protocols
  • • Up to 8-stage capture-and-study protocols
  • • User-defined protocols
  • • Wall motion scoring
  • • Stop/resume
  • ICE Imaging (Intracardiac Echocardiography)
  • • Catheter-based 2D echo imaging
  • • Includes Patient Isolation Module that allows HD11 XE to interface with EP MedSystems ViewFlex imaging catheters (available only from EP MedSystems)
  • • Velocity and variance displays
  • • Color/2D line density control
  • • Selection of color bar display units
  • • Color acquisition frame rates up to 320 frames per second
  • (dependent on probe, field of view, depth and angle)
  • Contrast Imaging
  • • System optimized for detecting harmonic agent signatures
  • • Variable low Mechanical Index (MI) and flash modes
  • • Pulse Inversion Harmonic imaging on the S3-1 transducer for
  • cardiac and abdominal applications and the C5-2 transducer
  • for general abdominal applications
  • • Start/Stop timer
  • • On-screen indicators are activated when contrast is selected
  • Tissue Harmonic Imaging (THI)
  • • Second harmonic processing reduces artifacts and improves
  • image clarity
  • • Incorporates patented pulse inversion phase cancellation
  • technology for maximum detail resolution during harmonic imaging
  • • Extends high performance imaging capabilities to all patient
  • body types
  • • Supports SonoCT and XRES modes
  • • Available on the S7-2omni, S7-3t, S4-2, S3-1, C5-2, BP10-5ec,
  • L12-3, L8-4, 3D9-3v, V6-2 and V8-4 transducers
  • Color Power Angio Imaging (CPA)
  • • Highly sensitive mode for small vessel visualization
  • • Available on all imaging transducers
  • • Fully user-configurable
  • • Cineloop review
  • • User-definable presets
  • • Multiple maps including directional CPA
  • • Individual controls for gain, filters, sensitivity, echo write priority
  • and color invert
  • • Adjustable CPA region of interest: size and position
  • • User-selectable persistence
  • • TGC control
  • • Write priority
  • • Color compare
  • System Specifications
  • Tissue Doppler Imaging (TDI)
  • • Color TDI uses color to display direction and timing of
  • myocardial function
  • • Pulsed wave Tissue Doppler Imaging (TDI) for velocity mapping of
  • cardiac tissue and vessel wall motion
  • • Available on all sector transducers
  • • Simultaneous or duplex mode of operation in conjunction with 2D,
  • color Doppler and color TDI
  • • LGC and TGC controls
  • Freehand 3D and MPR Imaging
  • • Qualitative grayscale volume acquisition supported on all
  • imaging transducers
  • • Volume display with surface rendering (transparency, brightness
  • and lighting controls)
  • • Multiplanar view display
  • • Specialized algorithms and maps maximize three dimensional
  • display
  • • Trim tools on both volume and multiplanar reconstructed
  • (MPR) views
  • • Supported by XRES to reduce noise artifacts
  • • Color compare
  • Automated 3D, 4D and MPR Imaging
  • • Quantitative 3D volume acquisition supported on V8-4, V6-2
  • and 3D9-3v transducers
  • • Ability to acquire and display up to 30 volumes per second in 4D
  • • Color 3D imaging
  • • High resolution scan and review mode
  • • Multiple display formats including full screen, 2-up and 4-up for
  • rendered volume and multiplanar images include full screen, 4-up
  • and expanded dual
  • • Volume display with surface rendering (transparency, brightness
  • and lighting controls)
  • • Specialized algorithms and maps maximize three dimensional
  • display
  • • Individual controls for manipulating the on-screen 3D rendering
  • and display options
  • • Region of Interest (ROI) trim tools on both volume and
  • multiplanar reconstructed (MPR) views
  • • V8-4, V6-2 and 3D9-3v transducers support XRES and SonoCT to
  • reduce noise artifacts
  • • Able to perform distance, ellipse, trace and volume measurements
  • Fetal STIC (Spatio-Temporal Image Correlation) Imaging
  • • Presents the heart beating in a multiplanar display, preserving
  • spatial and temporal relationships
  • • Utilizes MPR views and cine capabilities for evaluating fetal
  • heart anatomy
  • • System supports capabilities to perform the spin technique to
  • assess pathology
  • • Fetal Echo STIC supports image capture in gray scale only or
  • combined with Color Doppler
  • • Useful for easy detection of fetal heart anomalies during routine
  • obstetrical exams
  • Expanded Field of View
  • • Panoramic Imaging
  • – Extended field of view composite imaging
  • – Full zoom, pan, cineloop review and image rotation capabilities
  • – Available on linear, curved and sector (non-cardiac presets)
  • array transducers
  • • Trapezoidal imaging
  • – Expands field of view on linear array transducers up to 15
  • degrees on each side in vascular and general imaging applications
  • Stress Echo
  • • Fully integrated stress echo module
  • • 3 fixed protocols
  • • Up to 8-stage capture-and-study protocols
  • • User-defined protocols
  • • Wall motion scoring
  • • Stop/resume
  • ICE Imaging (Intracardiac Echocardiography)
  • • Catheter-based 2D echo imaging
  • • Includes Patient Isolation Module that allows HD11 XE to interface with EP MedSystems ViewFlex imaging catheters (available only from EP MedSystems)

System Cart

  • • Advanced ergonomic design
  • • Easy maneuverability and mobility
  • – Wheel-lock facilitates bedside exams
  • – Front and rear handles for portability
  • – Four-wheel swivel ability with two-wheel swivel lock and brakes
  • • Control panel
  • – Articulation facilitates optimal position up and down 7 in/18 cm
  • – Rotates 340 degrees
  • – Lighted alphanumeric QWERTY keyboard
  • • Flat panel LCD display monitor
  • – 20 in/51 cm high resolution flat panel TFT display
  • – 1280 x 1040 resolution at 60 Hz, non-interlaced RGB
  • – 0.258 mm pixel pitch
  • – Digital interface
  • – Extended viewing angle > 170 (horizontal and vertical)
  • – Virtually flicker-free technology reduces eye strain
  • – Backlight stabilization circuit to help maintain contrast and
  • extended LCD life
  • – Ambient lighting control for optimal image viewing in both light
  • and dark environments
  • – Mounted on fully articulating extension arm
  • – Four-way articulation with 10 inches of height adjustment
  • – Side-to-side lateral adjustment
  • – Nearly infinite positioning adjustments: height, swivel and tilt
  • • Transducer and gel bottle holders (removable for easy cleaning)
  • • Integrated footrest
  • • On-board storage in convenient pull-out bin located on front
  • of cart
  • • Universal peripheral bay and back deck provide easy access for
  • up to three on-board hardcopy/documentation devices
  • • Configurable with up to five active transducer ports
  • • Lighted area for easy visualization of transducer ports, storage
  • bin and disk drives
  • • Power supply meets IEC 60601-1.2: 2001 and Class B EMI
  • standards
  • • Three internal high-capacity impeller fans with automatic
  • speed adjustment to optimize cooling efficiency with minimal
  • audible noise
  • Control Panel and User Interface
  • • Easy-to-learn graphical user interface
  • • Primary controls readily accessible and logically grouped
  • • Commonly used secondary controls located on soft keys for
  • quick access; soft key functions change dynamically based on the
  • currently active mode, preset or system function
  • • Other secondary controls accessible through on-screen menus
  • • Alphanumeric QWERTY keyboard with world keys for conversion
  • to local language (English, French, German, Italian, Spanish
  • and Russian)
  •  
  • • User selectable keyboard stroke language (Roman, Kanji, Hiragana,
  • Katakana and Simplified Chinese)
  • • Trackball with Select and Enter keys for easy system navigation
  • • Integrated stereo speakers
  • • Imaging mode keys: 2D, 3D/4D, Color Power Angio imaging,
  • M-mode, color Doppler, Continuous Wave (CW) Doppler, Pulsed
  • Wave (PW) Doppler and TDI
  • • Image controls: Depth, Dual Left, Dual Right, Freeze, THI,
  • Zoom Focus
  • • Image enhancement controls: Dynamic Range, Focus, Gain,
  • Persistence, Post-processing Map, Smooth, Update
  • • Patient specific optimization keys: Fusion, Probe
  • (transducer select), THI
  • • iSCAN control for 2D/Doppler automatic optimization
  • • Quantitative controls: Calc, Caliper, Trace, Clear, Trackball
  • • Doppler/Color controls: Angle/Steer, Spectral, Scale, Baseline,
  • Gain 2D/M-mode, Gain Color/Doppler, Power, Volume
  • • Image Acquisition keys: Review, Report, VCR, Acquire and two
  • user-defined record keys supporting external print/video options
  • • Annotation controls: Label, Text, Clear, Arrow, Marker
  • (Bodymarker)
  • • Function keys: Microphone, Patient, Preset, Setup
  • • Two option keys activated with additionally purchased features
  • stress echo and contrast
  • • Online Help key
  • • Lateral Gain Compensation (LGC) slide pot controls
  • • Time Gain Compensation (TGC) slide pot controls
  • 3D/4D STIC Controls
  • • 3D/4D hard control
  • • ROI
  • • X,Y,Z controls for MPRs
  • • Axis icons
  • • Sculpt/Erase controls: Sculpt, Erase, Starts/Ends Editing, Undo,
  • Redo, Reset
  • • 3D preview controls for Color, CPA and Grayscale images: Size,
  • Position, Fan geometry, Angle selection and resolution settings
  • along with standard color controls where color is used
  • • 4D Preview controls: Size, Position, Angle, Resolution,
  • Compression, Map color, Smooth and Persist
  • • Color Fetal Echo STIC preview controls: Size, Position, Angle,
  • Acquisition Time, Compress, Map Color, Smooth and Persist
  • • Biopsy software for 2D biopsies with 4D probes
  • System Specifications

Physical Dimensions

  • Depth: 43.5 in/110.5 cm (no peripherals)
  • Width: 21 in/53.3 cm
  • Ground clearance: 4 in/10.2 cm
  • Height (adjustable): 59.5–68.5 in/151.1–173.9 cm
  • Control panel height (adjustable): 32.3–37.7 in/82–96 cm
  • Wheels: 5 in/12.7 cm diameter, 3.8 in/9.5 cm wide
  • Weight: 220 lbs/100 kg (no peripherals)
  • Flat panel monitor
  • iSCAN Intelligent
  • Optimization
  • Integrated DVD-R/RW,
  • USB flash drive support
  • Supports up to three peripherals on cart
  • Up to five transducer ports
  • Built-in footrest
  • Four-way swivel wheels
  • Media storage
  • Fully adjustable
  • control panel
  • Four-way
  • articulating arm
  • • Rendering controls for MPR, Volume, Render Edit ROI, 4D
  • Acquisition (Volume and ROI): Pan, X-Hair, Slice, Size, Acquire,
  • Rotate, Format, Sculpt/ Erase, Swivel, View, Resize, Reset
  • Threshold, Transparency, Brightness, Opacity, Reset, Smooth,
  • Next, Select
  • • Image controls: Render Mode in Grayscale, MPR Chroma, Volume
  • Chroma, Vision (Surface Vision), Invert, Invert with Color, Volume
  • Map, Render Mode, Adjust, Priority, Next, Select
  • • Edit ROI cine controls include Acquire 3D data, Format, Replay,
  • Render controls, Image controls, Accept ROI
  •  
  • • Volume cine MPR and Volume controls: Pan, X-Hair, Slice, Scroll,
  • Orbit, Rotate, Scroll, Acquire 3D data, Format, Replay, Render
  • Controls, Accept ROI, Sculpt/ Erase, Swivel, View, Edit Start, Edit
  • End and Reset
  • • Swivel Stopped and Playing controls: Orbit Rotate, Acquire 3D
  • Data, Left-Right Step, Min Angle, Max Angle, Play, Resume,
  • Reset, Speed, Stop, Step Size, Play Sequence, Next, Freeze,
  • Select, Acquire
  • Display Annotation
  • • On-screen annotation of all pertinent imaging parameters for
  • complete documentation, including transducer type and frequency
  • range, active clinical options and optimized presets, display depth,
  • TGC curve, grayscale, color map, frame rate, dynamic range,
  • compression and contrast enhancement, color gain, color image
  • mode, and hospital and patient demographic data
  • • User selectable display of patient birth date or user ID
  • • Annotation data and patient name can be turned off (hidden)
  • for generating images used in publication and presentation
  • • Sector Steering Icon for endocavitary transducers
  • • Scan plane orientation marker
  • • User selectable Depth Scale display
  • • Fusion setting, iSCAN, SonoCT and contrast icons
  • • Real-time display of Mechanical Index (MI)
  • • Real-time display of Thermal Index (TIb, TIc, TIs)
  • • Quick text allows easy annotation at any time during an exam
  • • Label—places, moves, erases, modifies or appends predefined text
  • labels, typed text or arrows
  • • Body markers—display body-part icons appropriate for the active
  • preset and indicates relative transducer position
  • – Icons selectable via trackball scroll
  • • Doppler baseline Invert in Live imaging
  • • TGC curve (user selectable On/Off display)
  • • TGC values (On/Off display)
  • • Calculations Results and Analysis labels
  • • Cineloop frame number display
  • • User selectable placement of measurement/calculations data box
  • Reporting
  • • On screen display of LMP and GA or GA and EDC for
  • Obstetric Exams
  • • Auto population of patient data if study with same MRN exists
  • on hard drive
  • • System provides application specific reports that provide
  • application specific information
  • • Ability to embed images into reports
  • • Measurement data can be entered directly into reports from
  • the ultrasound system
  • Image Presentation
  • • Up/down
  • • Left/right
  • • Multiple duplex image formats (1/3–2/3, 1/2–1/2, 2/3–1/3)
  • • Depth to 30 cm (exam/transducer specific)
  • Cineloop Review
  • • Acquisition, storage in memory and display in real-time and duplex
  • modes of up to 1,000 frames (four minutes in Quick Review) of 2D
  • and color images for retrospective review and image selection
  • • Single frames of Doppler data and M-mode images can be archived
  • to print or electronic media
  • • Supports two-buffer Dual Imaging mode of up to 500 frames
  • per buffer
  • • Trackball control of frame-by-frame image selection
  • • Variable playback speed
  • • Trim capability of 2D data
  • • Functions in 2D and Tissue Harmonic imaging, M-mode, PW
  • Doppler, CW Doppler, color Doppler, Color Power Angio imaging,
  • Tissue Doppler Imaging and Contrast imaging
  • Physio
  • • One 3-lead ECG input
  • • One external ECG input
  • • Two physio input channels (1V, p-p)
  • • Selectable ECG triggered skipping between 1 and 20
  • Connectivity
  • • 120 GB hard drive space (minimum)
  • • Standard with CD-R/RW, DVD-R/RW, USB flash drive support
  • • Direct digital storage of single frame color and B/W images to
  • internal hard disk, DVD, CD, and USB flash drive
  • • Direct digital storage of B/W and color loops to internal hard disk,
  • DVD, CD, and USB flash drive
  • • Stores a minimum of 900,000 B/W still frame images to internal
  • hard drive
  •  
  • • 4.7 GB DVD stores a minimum of 3,000 B/W still frame
  • images (RGB uncompressed format), or 9,000 B/W still frame
  • images (palette color uncompressed format) or 115,000 B/W
  • still frame images (YBR JPG compressed format at typical 16:1
  • compression ratio)
  • • Ability to export AVI clips and BMP images to CD, DVD or USB
  • flash drive for PC viewing
  • • Fully integrated interface
  • • Extensive image management capability, including thumbnails
  • image review, full screen image review, cineloop editing and
  • patient reporting
  • • Study manager allows user to digitally acquire and review
  • complete patient studies
  • • Exam directory
  • • Delete and replace recalled image capability
  • • Multiple study archive formats (palette color, RGB, YBR)
  • • DICOM 3.0 Print and Store services class user
  • • 10/100 BaseT Ethernet output
  • • Site configurable IP address, port ad AE title
  • • Perform Procedure Step (PPS)
  • • Modality Worklist with automatic entry of patient demographics
  • that works in conjunction with radiology and cardiology
  • information systems
  • • Structured Reporting (SR) includes Cardiology and Ob/Gyn
  • • Study reports available as DICOM images and HTML formats
  • • System can use lossy JPG image format with user configurable
  • compression ratio
  • • DICOM Networking option
  • – Print and Store service class user
  • – Performed Procedure Step (PPS)
  • – DICOM Worklist with RIS/CIS support and automatic patient
  • demographic entry
  • • Study reports available as DICOM images
  • • System can use lossy JPG image compression, ratio = 10:1–20:1
  • (typically 16:1)
  • • Philips RSN (Remote Services Network) Connectivity
  • – Supports rapid, advanced support delivered from anywhere
  • around the world
  • – Remote diagnostics for faster, more accurate equipment
  • evaluation
  • – Remote system status verification
  • – Routine preventative maintenance
  • – Uses secure, encrypted communications link
  • System Specifications

Peripheral Devices/Exam

  • System supports up to three on-board peripheral devices
  • (excluding report printers)
  • – Mitsubishi HS-MD3000 Super VHS VCR (USB controlled via
  • system user interface)
  • – Sony UP 21 MD digital color printer (USB)
  • – Sony UP895 small format digital B/W printer
  • – UPD 55MD large format color printer
  • – Support for various Hewlett-Packard brand printers
  • – Inkjet, LaserJet and Color LaserJet (USB, externally mounted)
  • – Export of measurement and analysis data to off-line reporting
  • software packages (USB) and PS-232 port to support obstetrical
  • data transfer
  • – Peripheral options come with shelf and cover
  • Input/Output ports
  • – Standard USB interface for support of qualified plain
  • paper printers
  • – B&W and color composite video: output to external monitor,
  • VCR or printer
  • – External print trigger
  • – LAN connector—used with DICOM networking
  • – Output DVI, 1280x1024 @ 60Hz
  • – S-video output for VCR, external monitor or printer
  • – Footswitch port for connecting the optional footswitch
  • – Serial Port for Remote service connection (Uplink ready), and
  • report Data Export
  • Selective Print
  • – Sends the type of data that makes the most sense for a particular
  • application, for example compressed data to a PACS system,
  • native data for QLAB
  • – Allows faster movement of data
  • – Allows selection of individual images to print in a batch
  • Security
  • Password protected access to patient data
  • Hardened operating system and application software
  •  
  • Electrical Power/Video Parameters
  • 100V–240V, 50Hz/60Hz
  • NTSC or PAL video formats
  • Integrated A/C line conditioning
  • Power consumption: 750VA–1000VA depending on system
  • configuration
  • 64 (6 bits) in M-mode
  • Power cords available for electrical standards worldwide
  • Uninterrupted power supply (UPS)
  • Safety Requirements
  • Electromechanical standards met
  • – C22.2 No. 601.1, Canadian Standards Association, Standard for
  • Medical Electrical Equipment
  • – JIS 60601-1, Japanese Standard for Medical Electrical Equipment
  • – EN 60601-1, European Norm, Safety of Medical Electrical
  • Equipment
  • – EN 60601-1-2, European Norm, Collateral Standard:
  • Electromagnetic compatibility
  • – EN 60601-2-37, European Norm, Particular requirements for the
  • safety of ultrasonic medical diagnostic and monitoring equipment
  • – UL 60601-1 Underwriters Laboratories Standard for Medical
  • Electrical Equipment
  • – AIUM/NEMA UD-2: 2004, Acoustic Output Measurement
  • Standard for Diagnostic Ultrasound Equipment
  • – AIUM/NEMA UD-3: 2004, Standard for Real-Time Display
  • of Thermal and Mechanical Indices on Diagnostic Ultrasound
  • Equipment
  • Agency approvals
  • – Canadian Standards Association (CSA)
  • – CE Mark in accordance with the European Medical Device
  • Directive 93/42/EEC
  • – Japanese Ministry of Health, Labor and Welfare
  • Miscellaneous System Data
  • Footswitch
  • Three pedals
  • Allows Freeze, Start/Stop Doppler scroll and Acquire
  • Includes two user-definable record functions
  • Localization Options
  • Software: English, French, German, Italian, Spanish, Simplified
  • Chinese, Japanese (Kanji, Hiragana, Katakana) and Russian
  • Training and user documentation: English, French, German,
  • Italian, Spanish, Japanese, Simplified Chinese, Polish, Portuguese
  • and Russian
  • Online help: English, French, German, Italian, Spanish, Portuguese,
  • Russian and Polish
  • Environmental
  • Temperature
  • – System: 0–40° C at 20–80% relative humidity (non-condensing)
  • – VCR and printers: 0–40° C at 80% relative humidity
  • (non-condensing)
  • Heat dissipation—<4000 BTUs/hour (fully loaded)

Measurements and Analysis

  • Measurement Tools and General Description
  • 2D distance
  • 2D circumference/area by ellipse, continuous trace, trace by points
  • 3D: ellipse and distance on 2 MPR views
  • M-mode distance (depth, time, slope)
  • Manual Doppler distance
  • Manual Doppler trace
  • Time/slope measurements in Doppler and M-mode
  • High Q automatic Doppler analysis
  • 2D volume
  • Heart rate
  • Trackball-controlled electronic measurement calipers: 8 sets
  • User-defined protocols, measurements and equations
  • On-the-fly measurement labels
  • Fully-editable results data sheet
  • Integrated patient exam report
  • Clinical Option Analysis Packages
  • Comprehensive measurements, calculations and applicationspecific
  • reports with imbedded images, including expanded cardiac,
  • vascular, Ob/Gyn and General Imaging capabilities for thorough
  • exam documentation
  • Cardiac analysis
  • – Volume by area/length method
  • – Ejection fraction (via Teichholz or cubed method)
  • – Simpson’s biplane and single plane
  • – LV mass
  • – M-mode analysis
  • – Doppler
  • – Peak and mean gradients
  • – Pressure half time
  • – E/A ratio
  • – Continuity equation
  • – Diastolic function
  • – Cardiac output
  • – Qp:Qs ratio
  • – Proximal Isovelocity Surface Area (PISA)
  • – TR max PG
  • – TR max
  • – PA V2 trace
  • – Ao dec time
  • – MV dec time
  • – MV dec
  • – PA dec time
  • – PA dec
  • – PA acel time
  • Vascular analysis
  • – Right and left carotid artery protocols measurements/analysis
  • package
  • – ICA/CCA ratio
  • – Right and left vertebral measurements
  • – Transcranial vasculature analysis package
  • – Right and left lower extremity analysis package
  • – Optional tools: percent diameter and area reduction
  • – User comments
  • – IMT trace
  •  Ob/Gyn and fertility analysis
  • – Fetal biometry
  • – Biophysical profile
  • – Amniotic fluid index
  • – Early gestation
  • – Fetal long bones
  • – Fetal cranium
  • – Nuchal translucency
  • – Other OB measurements:
  • - 2D echo
  • - Fetal heart M-mode
  • - Fetal Doppler
  • - Echo Doppler
  • - Fetal echo
  • – OB calculations and tables are user-definable
  • – OB trending data for up to ten studies per patient, 15 studies for
  • a patient plus the current study, including trending of MCA and
  • Umbilical Artery
  • – Display of up to 5 previous measurements on screen
  • – Display of Standard Deviation (SD)
  • – Automatic transfer of image to the report when a labeled
  • measurement or calculation is done
  • – Gynecology/Fertility
  • - Uterus
  • - Right and left ovary
  • - Right and left follicles
  • General Imaging analysis
  • – General abdominal
  • – Breast
  • – Prostate gland
  • – Pediatric general
  • – Pediatric hips
  • – Musculoskeletal
  • System Specifications
  • QLAB Advanced Quantification Plug-in Options
  • Intima Media Thickness (IMT) Quantification Plug-in
  • – Automated assessment of the IMT on user-selected frames
  • – For carotid and other superficial arteries
  • Region of Interest (ROI) Quantification Plug-in
  • – Up to 10 user-defined regions
  • – Thumbnail display of frames for easy trimming
  • – Pixel intensity analysis, data types: echo, velocity or
  • power (angio)
  • – TDI velocity timing measurements
  • Strain Quantification (SQ) Plug-in
  • – For evaluation of regional myocardial function, assessment
  • of synchronicity and guidance during bi-ventricular
  • pacing procedures
  • – Tissue Doppler Imaging (TDI) velocity quantification
  • – Measures the myocardial velocity and derives the strain rate and
  • strain along user defined M-lines
  • – Capable of drawing up to three M-lines at a time
  • – Point of Interest (POI) tool obtains values from any point on the
  • M-mode display
  • – User defined M-line motion to follow the myocardial motion
  • – Able to present TDI results in two display formats:
  • - Anatomical M-mode display
  • - Graph display
  • – User-selectable waveforms for optimal sub-region visualization
  • – New curve processing modes
  • – TDI velocity timing measurement
  • – Automatic subdivision of M-line into a customizable number
  • of sub-regions
  • – Averages up to 20 cardiac beat cycles in both M-mode and
  • graph displays
  •  Cardiac 2D Quantification (2DQ) Plug-in
  • – Display of 2D ultrasound images
  • – Overall, vertical and horizontal gain controls
  • – Semi-automated border detection for cardiac chambers and
  • vessel cavities
  • – Color Kinesis (CK) tool for displaying mitral valve annular
  • motion over time parametrically
  • – Transparency control to visualize echo grayscale under a
  • semi-transparent CK image
  • – CK for arbitrary frame rates
  • – CK for the mitral annulus (which represents the basal terminus
  • of the LV endocardium)
  • – Manual user-editable timing overrides for the onset and duration
  • of the parametric display
  • – Single-plane volume measurements based on the 5/6
  • Area-Length Method and Simpson’s Singleplane Method of
  • Disks (MOD)
  • General Imaging 3D Quantification (GI 3DQ)
  • – View, crop, rotate, access and use all vision controls
  • – Advanced quantification tool for intelligent volumetric
  • slicing (iSlice)
  • – Quick exploration and documentation of volumetric data
  • – Advanced slice control including spacing and thick slice displays
  • – Full measurement capability
  • – Perform everyday measurements on 3D ultrasound images:
  • - Elevation resize for freehand volumes
  • - Linear measurements
  • - Angle determination
  • - Ellipse measurements
  • - Stacked contour measurements
  • - Stacked ellipsoid measurements
  • - Ellipsoidal volume measurements
  • High Q Automatic Doppler Analysis
  • Automatic real-time and retrospective tracing of:
  • – Instantaneous peak velocity (or frequency)
  • – Instantaneous intensity weighted mean velocity (or frequency)
  • Vascular
  • – Automatic real-time display of:
  • - Volume flow
  • - Time-averaged peak velocity (or frequency)
  • - Time-averaged mean velocity (or frequency)
  • - Resistive index
  • - Pulsatility index
  • - Systolic/diastolic ratio
  • - Acceleration/deceleration times
  • Cardiology (pulsed wave only)
  • – Automatic real-time display of:
  • - Peak velocity
  • - Peak gradient
  • – Display of:
  • - Cardiac output
  • - VTI
  • - Mean velocity
  • - Mean gradient

 

Philips Models

  • PHILIPS HDI 5000

  • PHILIPS HDI 3000

  • PHILIPS HD 11

  • PHILIPS HD 11 XE

  • PHILIPS ENVISIOR

  • PHILIPS IE33

Contact Us

877-891-0084 877-891-0084

or use the form below






SONODEPOT HEADQUARTERS

Eight East Twelfth Street
St. Cloud, FL 34769-3937
(877) 891-0084 Hotline
(407) 892-5577 Office
(407) 892-0564 Fax

Contact Us Contact Us

Ultrasound Services

Skip navigation
  • Ultrasound Repair
  • Transducer Repair
  • Probe Evaluation
  • Ultrasound Service Contracts
 

Equipment Sales

Skip navigation
  • New C-Arm Solutions
  • New Ultrasound Equipment Sales
  • Used Ultrasound Equipment Sales
  • Portable Ultrasound Equipment Sales
  • Alpinion E-Cube
 

SOCIAL

  • Facebook

Copyright 2021  SONODEPOT  All Rights Reserved. Privacy Policy.    site by PH3